北京中仪伟信科技有限公司
主营产品:DL750示波器  DL750示波器  F123示波表  F199B示波表  TDS2024B数字存储示波器  TPS2012存储示波器  
繁体中文  
 产品搜索:
  

美国福禄克FLUKE MPS450患者模拟仪

美国福禄克FLUKE MPS450患者模拟仪
如果您对该产品感兴趣的话,可以
产品名称: 美国福禄克FLUKE MPS450患者模拟仪
产品型号: MPS450患者模拟仪
产品展商: 北京中仪伟信科技有限公司
品牌厂商: 美国福禄克FLUKE
发布时间: 2010-4-30 17:47:53  

简单介绍
准确度:±2%

美国福禄克FLUKE MPS450患者模拟仪的详细介绍

产品特点:


MPS450患者模拟仪Overview
The MPS450 is Fluke Biomedicals next-generation, portable, multiparameter patient simulator for your comprehensive testing training needs. Cardiac Output Fetal/Maternal ECG models are also available. (See “Models.”)
SMPS450患者模拟仪tard Features

  • ECG simulation/12-lead independent outputs
  • 43 arrhythmia selections
  • Four invasive BP channels including Swan-Ganz
  • Respiration simulation
  • Temperature simulation
  • BP synonization with ECG
  • Large, bright 4-line by 20-acter super twist display
  • R-Wave detection test
  • 9 V battery operation
  • External battery tests (9 V)
  • RS-232 port for computer control
  • Compact size
  • Front-panel soft-key user interface
  • Universal ECG connectors
  • High-level ECG output
  • Expansion port

MPS450患者模拟仪Optional Features

  • Cardiac-output simulation
  • Fetal/maternal ECG, direct simulations with intrauterine-pressure waveform (IUP)
  • Remote controller HHC3 (Hheld Controller)

 

Specifications
Power
 
Two 9 V alkaline batteries (eight hours min continuous power).
 
Optional battery eliminator
Normal-Sinus-Rhythm Waveform
ECG Reference:
ECG amplitudes specified for Lead II (calibration), from the baseline to the peak of the R-Wave; other leads proportional
Normal Sinus Rhythm:
12-lead configuration with independent outputs referenced to right leg (RL); output to ten Universal ECG Jacks, color-coded to AHA IEC Stards
Low-Level Amplitude:
0.05 to 0.50 mV (0.05-mV steps); 0.5 to 5.5 mV (0.5-mV steps) (Power-on default: 1 mV)
Amplitude Accuracy:
± 2 % of setting Lead II
High-Level Output:
(available on the BP3 connector) 0.2 V/mV ± 5 % of the ECG-amplitude setting
ECG Rate:
30, 40, 45, 60, 80, 90, 100, 120, 140, 160, 180, 200, 220, 240, 260, 280, 300 BPM (Power-on default: 80 BPM)
Rate Accuracy:
± 1 % of setting
ECG-Waveform Selection:
Adult (80 ms) or pediatric (40 ms) QRS duration (Power-on default: adult QR/P-R interval of 0.16 seconds)
Superimposed Artifact:
50 60 Hz, muscle, baseline wer, respiration
ST-Segment Elevation/Depression:
Adult mode only, -0.8 mV to +0.8 mV, in 0.1-mV steps; additional steps, +0.05 mV -0.05 mV (Power-on default: elevation 0 mV)
Pacemaker Waveform
Pacer-Pulse Amplitude:
1, 2, 5, 10 mV, ± 10 % (Power-on default: 5 mV)
Pacer-Pulse Width:
0.1, 0.5, 1.0, 1.5, 2.0 ms, ± 5 % (Power-on default: 1.0 ms)
Pacing Rate:
75 BPM
Waveforms:
(Power-on default: atrial waveform)
 
- Atrial
 
- Asynonous 75 BPM
 
- Dem with frequent sinus beats
 
- Dem with occasional sinus beats
 
- AV sequential
 
- Noncapture (one time)
 
- Nonfunction
Arrhythmias
Baseline NSR:
80 BPM
PVC Focus:
Left focus, stard timing (except where specified)
Supraventricular Arrhythmias:
(Power-on default: atrial fibrillation, coarse)
 
- Atrial fibrillation, coarse
 
- Atrial fibrillation, fine
 
- Atrial flutter
 
- Sinus arrhythmia
 
- Missed beat (one time)
 
- Atrial tachycardia
 
- Paroxysmal atrial tachycardia (PAT)
 
- Nodal rhythm
 
- Supraventricular tachycardia
Premature Arrhythmias (all one-time events):
(Power-on default: premature atrial contraction)
 
- Premature atrial contraction (PAC)
 
- Premature nodal contraction (PNC)
 
- PVC1 left ventricular
 
- PVC1 left ventricular, R on T
 
- PVC2 right ventricular
 
- PVC2 right ventricular, early
 
- PVC2 right ventricular, R on T
 
- Multifocal PVCs
Ventricular Arrhythmias:
(Power-on default: PVCs 6/min)
 
- PVCs 6/min (Power-on default)
 
- PVCs 12/min
 
- PVCs 24/min
 
- Frequent multifocal PVCs
 
- Bigeminy
 
- Trigeminy
 
- Multiple PVCs (one-time run of 2PVCs)
 
- Multiple PVCs (one-time run of 5 PVCs)
 
- Multiple PVCs (one-time run of 11 PVCs)
 
- Ventricular tachycardia
 
- Ventricular fibrillation, coarse
 
- Ventricular fibrillation, fine
 
- Asystole
Conduction Defects:
(Power-on default: first-degree heart block)
 
- First-degree heart block
 
- Second-degree heart block
 
- Third-degree heart block
 
- Right-bundle-branch block
 
- Left-bundle-branch block
ECG-Performance Testing
Amplitude:
0.05 to 0.50 mV (0.05-mV steps); 0.5 to 5.5 mV (0.5-mV steps) (Power-on default: 1 mV)
Pulse Wave:
30, 60 BPM, with 60 ms pulse width
Square Wave:
2, 0.125 Hz (Power-on default: 2 Hz)
Triangle Wave:
2, 2.5 Hz
Sine Wave:
0.5, 5, 10, 40, 50, 60, 100 Hz
R-Wave-Detection Waveform:
Haver-Triangle
R-Wave Rate:
30, 60, 80, 120, 200, 250 BPM (Power-on default: 60 BPM)
R-Wave Width:
20 to 200 ms (10-ms steps); additional steps, 8, 10, 12 ms (Power-on default: 10 ms)
Rate Accuracy:
± 1 %
Amplitude Accuracy:
± 2 %, Lead II (exception, ± 5 % for R-Waves ≤ 20 ms)
Respiration
Rate:
0 (OFF), 15, 20, 30, 40, 60, 80, 100, 120 BrPM (Power-on default: 20 BrPM)
Impedance Variations (∆Ω):
0.2, 0.5, 1, or 3 Ω (Power-on default: ∆ 1 Ω )
Accuracy Delta:
± 10 %
Baseline:
500, 1000, 1500, 2000 Ω, Leads I, II, III (Power-on default: 1000 Ω)
Accuracy Baseline:
± 5 %
Respiration Lead:
LA or LL (Power-on default: LA)
Apnea Selection:
12, 22, or 32 s (one-time events), or continuous (Apnea ON = respiration OFF) (Power-on default: 12 s apnea)
Blood Pressure
Input/Output Impedance:
300 Ω ± 10 %
Exciter-Input Range:
2 to 16 V RMS
Exciter-Input-Frequency Range:
DC to 5000 Hz
Transducer Sensitivity:
5 or 40 µV/V/mmHg (Power-on default: 5 µV/V/mmHg)
Pressure Accuracy:
± (2 % of setting + 2 mmHg)
Static Levels, P1: -
10, 0, 80, 160, 240, 320, 400 mmHg (Power-on default: 0 mmHg)
Static Levels, P2: -
10, 0, 50, 100, 150, 200, 240 mmHg (Power-on default: 0 mmHg)
Static Levels, P3: -
5, 0, 20, 40, 60, 80, 100 mmHg (Power-on default: 0 mmHg)
Static Levels, P4: -
5, 0, 20, 40, 60, 80, 100 mmHg (Power-on default: 0 mmHg)
Dynamic Waveforms, P1:
 
- Arterial:
120/80
- Radial artery:
120/80
- Left ventricle:
120/00
- Right ventricle:
25/00
Dynamic Waveforms, P2:
 
- Arterial:
120/80
- Radial artery:
120/80
- Left ventricle:
120/00
- Right atrium (central venous or CVP):
15/10
- Right ventricle:
25/00
- Pulmonary artery:
25/10
- Pulmonary-artery wedge:
10/2
- Left atrium:
14/4
Dynamic Waveforms, P3:
 
- Arterial:
120/80
- Radial artery:
120/80
- Left ventricle:
120/00
- Right atrium (central venous or CVP):
15/10
- Right ventricle:
25/00
- Pulmonary artery:
25/10
- Pulmonary-artery wedge:
10/2
- Left atrium:
14/4
Dynamic Waveforms, P4 (Swan-Ganz Sequence):
Right atrium (CVP); right ventricle RV); pulmonary artery (PA); pulmonary-artery wedge (PAW)
Respiration Artifact:
BP delta change from 3 to 16 mmHg
BP Output:
Mini DIN 7-Pin
Temperature
Temperature:
0 °C (32 °F), 24 °C (75.2 °F), 37 °C (98.6 °F), 40 °C (104 °F) (Power-on default: 0 °C / 32 °F)
Accuracy:
± 0.1 °C
Compatibility:
Yellow Springs, Inc. (YSI) Series 400 700
Output:
mini DIN 7-pin
Cardiac Output (optional)
Catheter Type:
Baxter Edwards, 93a-131-7f
Calibration Coefficient:
0.542 (0 °C injectate), 0.595 (24 °C injectate)
Blood Temperature:
37 °C (98.6 °F) ± 2 %
Injectate Volume:
10 cc
Injectate Temperature:
0 °C or 24 °C ± 2 % value (Power-on default: 0 °C injectate)
Cardiac Output:
2.5, 5, 10 lpm ± 5 % (Power-on default: 2.5 lpm)
Faulty-Injection Curve:
(Waveform for simulation available)
Left-to-Right-Shunt Curve:
(Waveform for simulation available)
Calibrated Pulse:
1.5 ° for 1 second (37 ° * 35.5 °) (Waveform for simulation available)
Repeatability:
± 1 %
Fetal/Maternal ECG (optional)
Maternal Heart Rate (Fixed):
80 BPM
Fetal Heart Rate (Selectable):
60, 90, 120, 140, 150, 210, 240 BPM (Power-on default: 120 BPM)
Fetal Heart Rate (IUP):
140 BPM at beginning, then varying with pressure
Intrauterine-Pressure Waveforms:
- Uniform acceleration (140-175-140 BPM; rate change lagging IUP contraction by 30 s)
 
- Uniform deceleration (140-100-140 BPM; rate change lagging IUP contraction by 30 s) (Power-on default)
 
- Early deceleration (140-100-140 BPM; no IUP lag time)
 
- Late deceleration (140-100-140 BPM, starting at IUP peak)
Wave Duration:
90 seconds, bell-shaped pressure curve, from 0 to 90 mmHg returning to 0, ± 4 mmHg (max)
IUP Period:
2, 3, or 5 minutes; manual (Power-on default: manual)
Computer Setup
Port:
Bidirectional (Data Communications Equipment) RS232
Baud Rate:
9600
Parity:
None
Stop Bits:
1
Data Bits:
8
Battery Replacement
 
Warning for low-battery condition (batteries to be replaced at this time)
Temperature
Storage:
-25 to 50 ºC
Operation:
10 to 40 ºC
Huity
 
80 % max relative huity
Dimensions
 
7.5” L x 7.25” W x 2” H
 
(19 cm L x 18.415 cm W x 5 cm H)
Weight
 
1.35 lb
 
(.612 kg)

 

型号名称
描述
 MPS450
 MPS450 Patient Simulator (part #2251364)
Includes:
  • ECG 12-lead simulation
  • invasive BP
  • respiration
  • temperature
  • BP in sync with ECG
  • large, bright 4-line by 20-acter display
  • R-Wave-detection test
  • RS232 port for computer control
  • soft-key navigation
  • universal ECG connectors
  • flash memory for easy program upgrade
  • User manual (part #2243350)
  • AC battery eliminator (part #2720054)
 MPS450-CO
 MPS450 Patient Simulator (part #2251373)
Includes:
  • base model
  • cardiac-output simulation
  • Operators User manual (part #2243350)
  • AC battery eliminator (part #2720054)
 MPS450-FET
 MPS450 Patient Simulator (part #2251399)
Includes:
  • base model
  • direct fetal/maternal ECG simulations with maternal heart rate
  • selectable fetal heart rate
  • dynamic intrauterine pressure waveform [IUP]
  • Operators User manual (part #2243350)
  • AC battery eliminator (part #2720054)
 MPS450-CO/FET
 MPS450 Patient Simulator (part #2251386)
Includes:
  • base model
  • cardiac-output simulation
  • direct fetal/maternal ECG simulations with maternal heart rate
  • selectable fetal heart rate
  • dynamic intrauterine pressure waveform [IUP]
  • Operators User manual (part #2243350)
  • AC battery eliminator (part #2720054)
 
Related Products
HHC3
HHC3 手持式控制器
FBC_A_ADAPT
Temperature Adapter
 
Cable Adapter
 
General Purpose Connector
 
 
FBC_A_CABLE
Blood Pressure Cable Burdick Datex P&B
 
Blood Pressure Cable Corometrics 12 PIN
 
Blood Pressure Cable Corometrics 3P3S
 
Blood Pressure Cable Gould/Statham
 
Blood Pressure Cable Marquette 7000 (
 
Blood Pressure Cable Universal Asby
 
Blood Pressure Cable, Marq Eagle B
 
BP Cable HP 12-PIN
 
BP Cable HP 5-Socket
 
BP Cable Marquette Twin Asby
 
BP Cable Mennen Med
 
BP Cable Nihon Khoden
 
BP Cable Phys-C Vitat Tek
 
BP Cable Siemens 10-PIN
 
BP Cable S-Labs Sqib Vita
 
Cable Asby Gould 1445 INJ
 
Cable Asby Gould 1465 INJ
 
Cable Asby HP Injectate
 
Cable Asby Universal C/O
 
Cable Co Marq Eagle
 
Cable Data Scope
 
Cable Parallel Printer
 
Temperature Cable Asby 400 Series
 
 
FBC_A_CASE
9530-0072
 
 
FBC_A_MISC
Cardiac Output Box
 
 
 

 

 

产品留言
美国福禄克FLUKE MPS450患者模拟仪  留  言
产品名称:
公司名称: *
联 系 人: *
电    话: *
传    真:
电子邮件:
留    言: *
注:如有必要,请您留下您的详细联系方式,以便我们及时解决您的问题! 
如果您对美国福禄克FLUKE MPS450患者模拟仪感兴趣请点击    收藏此页

美国福禄克FLUKE MPS450患者模拟仪相关产品

Copyright@ 2009  北京中仪伟信科技有限公司 Power By 就要示波器 版权所有      京ICP备09069938号   
优化关键词:  示波器 万用示波表 数字示波器 模拟示波器 虚拟示波器 波形示波器 信号发生器 函数发生器 代理商售后维修区域:北京-上海-浙江-广东-河南-杭州-郑州-广州-深圳-佛山-惠州-厦门-汕头-台湾-香港-天津-西安-宝鸡-杭州-温州-常州-无锡-苏州-南京-镇江-扬州-南通-合肥-徐州-常熟-石家庄-太原-呼和浩特-沈阳-长春-哈尔滨-南京-合肥-福州-南昌-济南-郑州-武汉-长沙-广州-南宁-海口-成都-贵阳-昆明-拉萨-西安-兰州-西宁-银川-乌鲁木齐-杭州-沈阳-长春-哈尔滨-济南-武汉-广州-南宁-成都-西安-大连-宁波-厦门-青岛-深圳-杭州-淮安-连云港-昆山-嘉兴-